What is a PRI Line, what are the advantages and limitations of PRI circuits

By Rajesh K

This article explains what a PRI line is, what are the benefits of having PRI lines for the telephony requirements of an organization, and the dis-advantages of a PRI line.

 

PRI Line Connectivity and Architecture Diagram

What is a PRI line?

  • There is only one line physically terminating on the customer PBX but still a PRI line can receive/send 30 calls simultaneously! A PRI line is end to end digital circuit.
  • A PRI (Primary Rate Interface) line is a form of ISDN (Integrated Services Digital Network) line which is a telecommunication standard that enables traditional phone lines to carry voice, data and video traffic, among others.
  • A PRI circuit consists of two pairs of copper lines terminating on a modem from a service provider premises to the customer premises. It uses multiplexing/de-multiplexing techniques to carry more than one channel in a single circuit. There are two common forms of PRI lines – E1 (which carry 30 channels in the two pairs of copper lines, common in Europe, India) and T1 (which carry 23/24 channels in the two pairs of copper lines, common in United States).
  • Each channel in a PRI line provides 64 Kbps for data transmission.
  • A PRI line can connect to both Analog/Mixed EPABX systems and also the newer IP PBX systems. A PRI Card / Interface might be required to terminate the PRI circuit on the PBX.
  • A PRI line can also be used to connect two PBX systems thereby providing 30 channels between them for interoperability.

Advantages of PRI Lines:

If thirty separate analog trunks are taken instead of one PRI line,

  • The cost of terminating all the thirty analog trunk lines becomes higher than terminating one PRI line.
  • There would be thirty rentals to be paid instead of one consolidated lower rental for a PRI line.
  • Some analog trunks might be used more (uneven distribution of calls) and some lines may not have even crossed the free calls limit.
  • Terminating 30 analog trunks in a PBX also requires more free slots/cards than the one slot usually occupied by one or even two PRI trunk cards.
  1. Direct Inward Dialing: For each PRI line, the service provider would provide more around 100-500 numbers which can be used by outsiders to call the extension directly, instead of having to go through the PBX Auto-attendant.
  2. Caller ID: Since all the extensions have their own number, this unique number will be displayed in the phones that they are calling to. Some call centre applications are based on the unique caller ID number for differentiation of services.
  3. It is possible to offer both voice and data in the PRI line. Some service providers have dynamic offerings where data is transmitted in all the channels that are free (not occupied by voice) at that given point of time.
  4. Call hunting (Where the call lands in any channel that is free, instead of the called number specifically – For example, if there is one board number but a number of people are calling in at the same time and still a channel is allocated to them .With analog lines, if one number is busy, they need to call in another number manually) is possible by default with a PRI connection, but for the analog trunks this facility needs to be extended by the service provider and enabled on the PBX, involving additional cost at times.
  5. PRI lines can be used for voice connectivity, data connectivity, video conferencing, faxing, and all the above can be done simultaneously too (on different channels).
  6. PRI lines are end-to-end digital lines and hence the clarity is much better than analog trunk lines.
  7. Since they are digital lines, PRI lines are more reliable and trouble shooting is also easier with them. They are mostly on a fiber core ring and hence there is some redundancy.
  8. It is harder to tap into digital lines and listen to the conversations.
  9. There are flexible billing options available with most of the PRI service providers. The billing can be centralized or distributed (department wise, etc).
  10. PRI lines take lesser time to establish calls then analog trunk lines.
  11. Some service providers offer flexible plans where instead of the full 30 channels, they provide and charge for only 20 channels etc. This makes PRI lines more economical for smaller companies.

Dis-advantages of PRI lines:

  1. A PRI line is economical only if the minimum rental charged by the service provider for a PRI line is more than the average value of calls with analog trunk lines every month in an organization. Otherwise, the usage may not even cross the free call value provided by the service provider for a PRI line.
  2. A PRI line is not so economical for long distance/ international calling. An ITSP or SIP trunk service provider who takes the calls over the internet might charge much lesser for international long distance calls.
  3. Inter branch communication between the branches is not free of cost with PRI lines (Some PRI service providers provide this facility, but all your branches may need to have PRI lines from the same service provider and there also might be a minimum revenue commitment for the same). With VOIP systems, inter-branch communication can be done over internet/ leased lines hence reducing the cost drastically.
  4. The cost of a single PRI card to connect to your EPABX/ IP PBX is still very high. Most of these cards are proprietary, meaning you can buy them only from your EPABX vendor.

 Related Article: Difference between Analog Trunk Lines, PRI/E1/T1 Lines & GSM Gateway.

excITingIP.com

You can receive email updates when new articles are published in this website, by submitting your email address in the sidebar box that says, ‘Get email updates when new articles are published’.

 

Tags: , , , , , , , ,

122 Responses to “What is a PRI Line, what are the advantages and limitations of PRI circuits”

  1. how can i get PRI LINE

    #134619
  2. Dear Rajesh
    kindly update the status

    #134629
  3. Mike

    Excellent summary. Thanks!

    #142653
  4. Sam

    Can PRI card take BRI inline ?

    #146008
  5. Paresh patel

    Thanks for information !!

    #148781
  6. shiv

    How can i get the PRI Lines

    #155321
  7. Sid

    What is the reason for drop in revenues in per line of PRI’s these days? There seems to be fall in the revenue generated according to recent analysis

    #158838
  8. Seetharam

    How to check whether pri line is working from. Modem to pbx end

    #160209
  9. jay

    Dear All

    thare are PRI teasters availabeinmarket with which you can check your pri line…

    Reliance’s pri line isbest as i expereinced….

    #161447
  10. Paeash

    I am very happy. this is very needful for me & all..

    Thanks…

    #175369
  11. Really helpful…in US we use T1 lines binded together on 1 PBX system.

    T1 E1 E1 T1
    PBX—–MUX—-((( IP Network )))—-MUX—-PBX

    #183522
  12. puneet dudi

    HI,
    I just want to do Infrastructural setup for bulk audio calling/SMS having the capacity 50,000 calls per day. For that I need 5 PRI lines. Do any one have any idea, who can provide me the best Software & Hardware solution for this.
    Thanks
    Puneet

    #190074
  13. Musleh

    Hi Sir,
    I need to install a fax solution using PRI/T1 line to divert (logically from Service provider side) all land line fax number to that PRI/T1 line & connect this PRI/T1 line to server by adapter/card to Control those lines by windows fax service.
    I need your kind consultation for the below questions:
    1- Is it possible to use this in any fax server solution that integrated with Windows Fax Service?
    2- Can Windows Fax Service see all fax numbers separately to receive Faxes for each line?
    3- Finally, which HW Adapter/Card solution to link PRI/T1 line to server that’s suitable and recommended for this project?

    Thanks for your time.

    #191894
  14. Surendra

    REALLY VERY HELPFUL. THANKS

    #194377
  15. how many call at a time of this line,

    can i send multiple SMS through this line

    #196803
  16. Vignesh Muthaiah

    Hi i’m Vignesh currently working in desktop Support Engg and Completed CCNA, now i got job in TTSL ( Tata )is network engg but Field work, like PRI ,Voice & Data ,Cisco Routers config ,now please suggest me ,how about future of this job & salary growth in future , this is good field, please

    #200265
  17. Robinson

    Can I Connect One PRI Card on a PABX Machine directly to another PRI card on another PABX Machine without using a modem. The distance between the two PABX Machines is 300M.
    Thank you

    #200684
  18. John

    actually i am not voice Eng can any one help me out with easy and simple explanation so i can understand properly .. actually i am work on design and implementation and our design we use PRI for voice. that i know only so how to figure out how PRI work and how its take action in network environments

    #210727
  19. Hi,
    I m working as dialer manager in a company which name is serco bpo and basically i used to dialed for ROb and kolkata circle and i have 60 chanells for both the circle to dialed through genesys dialer,but i have a issue that i m unable to control abndoned %, my total manpower is 85 if i will dialed 1:1.5 ratio still the issue is happening and if i will dialed against 1:1 ratio then my process avail% is getting high,,
    please help me out zbt this serious concern and im really worried abt it.

    #211845
  20. Uraia

    This is a really neat explanation.

    #211884
  21. TJ

    Great article! Helpful to get the basic concept of PRI. Thanks for making this :)

    #219808
  22. JR

    Question on a PRI with an existing DID can I insert or Drop a Whole Number not related with the DID range?

    #232619
  23. Tiao

    Please can you write an article on both SIP and SIP-I. Still can’t get a full grip on the two protocols. Thank you.

    #243205
  24. raj

    i have t he requirement as follows:
    10 B channel PRI
    4 Analog extensions
    10 Digital Extensions
    40 SIP licenses .
    can you let me know how many number of PRI d0 need.and explain why you selected the particular number of PRI

    #245423
    • You can replace the 10 B channel BRI, with one PRI line. Of course, you also need to buy the appropriate PRI interface card from your PBX vendor. One PRI can carry 30 channels, but one BRI can carry only 2 channels of voice.

      #245801

Leave a Reply